Fault code list for Kalmar forklift trucks

fault code list for kalmar forklift trucks
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
1Communication error with Control unit attachment (D791-1).Attachment functions not working.Use diagnostic menu to find incorrect segment.D791-1CAN/ POWER,menu 211.6.2 Redundant CAN-bus
2Communication error with Control unit attachment option (D791-2).Levelling, tilt, overheight extension not working.Use diagnostic menu to find incorrect segment.D791-2CAN/ POWER,menu 211.6.2 Redundant CAN-bus
3Communication error with Control unit attachment left legs (D791-3).Left side of bot- tom lift not working.Use diagnostic menu to find incorrect segment.D791-3CAN/ POWER,menu 211.6.2 Redundant CAN-bus
4Communication error with Control unit attachment right leg pair (D791-4).Right side of bot- tom lift not working.Use diagnostic menu to find incorrect segment.D791-4CAN/ POWER,menu 211.6.2 Redundant CAN-bus
5Communication error with Control unit frame rear (D797-R).Lighting rear, hydraulic oil cooling, overload system, extension not working.Use diagnostic menu to find incorrect segment.D797-RCAN/ POWER,menu 211.6.2 Redundant CAN-bus
6Communication error with Control unit frame front (D797-F).Front lighting, lift, extension, brake light, brake cooling not working.Use diagnostic menu to find incorrect segment.D797-FCAN/ POWER,menu 211.6.2 Redundant CAN-bus
7Communication error with Control unit frame option (D797-O).Sliding cab, support jacks, joystick steering mini-wheel, cab lift and cab tilt not working.Use diagnostic menu to find incorrect segment.D797-OCAN/ POWER,menu 211.6.2 Redundant CAN-bus
8Communication error with Control unit KID (D795).Controls in steering wheel panel and dis- play not working.Use diagnostic menu to find incorrect segment.D795CAN/ POWER,menu 211.6.2 Redundant CAN-bus
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
9Communication error with Control unit cab option (D790-3).Mini-wheel or joystick steering not workingUse diagnostic menu to find incorrect segment.D790-3CAN/ POWER,menu 211.6.2 Redundant CAN-bus
11Cable defect CAN-net segment 1.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
12Cable defect CAN-net segment 2.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
13Cable defect CAN-net segment 3.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
14Cable defect CAN-net segment 4.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
15Cable defect CAN-net segment 5.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
16Cable defect CAN-net segment 6.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
17Cable defect CAN-net segment 7.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
18Cable defect CAN-net segment 8.No limitation.Use diagnostic menu to find incorrect segment.Varies depending on machine configuration.CAN/ POWER,menu 1and 2111.6.2 Redundant CAN-bus
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
20Accelerator pedal (B690) not calibrated.Poor sensitivity in accelerator pedal.Calibrate the accelerator pedal, see tab 8 Control system, group8.5.2.3 Calibrate DRIVE-TRAIN.D790-1/ K6:11 – B690CALIBRA- TION: DRIVE- TRAIN,menu 1and 21. Engine
21Communication error with Control unit transmission (D793).Gear selection not working.Use diagnostic menu to check communication.Check cable harness between Control unit cab (D790-1) and Con- trol unit transmission (D793).D790-1/ K13:1 – D793/M2D790-1/ K13:2 – D793/L2CAN/ POWER,menu 311.6.3CAN-bus drive train
22Communication error with Control unit engine (D794).Engine does not react to commands from cab.Use diagnostic menu to check communication.Check cable harness between Control unit cab (D790-1)and Control unit engine (D794).Volvo: D790-1/ K13:1,K13:2 – D794/2, 1Cummins: D790-1/ K13:1,K13:2 – D794/46, 37CAN/ POWER,menu 311.6.3CAN-bus drive train
23The setup file cannot be read in Control unit cab (D790-1).No controls working in cab.Contact Kalmar Indus- tries AB.D790-111.5.3.1Control unit cab
24Electric power feed to cab fan less than 18 V.Cab fan not working.Check fuse F58-5/3.D790-1/ K2:8 – 58- 5/3:29.4.3 Cab fan
25Interference during soft- ware download. Buffer for error codes from Control unit engine (D794), active error code when downloading.Error code is stored in Control unit engine (D794).Turn the ignition off and on.Repeat software download.D794ENGINE,menu 811.5.3.10Control unit engine
26
27
28
29
30
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
31Incorrect electric power feed to Control unit cab (D790-1). Voltage lower than 18 V or higher than 32 V.Control in cab not working.Check fuse F58-5/1.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D790-1/ K1:2, K1:3, K1:4 – F58-5/1:1, 1:2CAN/ POWER,menu 611.5.1.3 Ignition voltage (15)
32Incorrect 5 V reference voltage to analogue controls in the cab. Volt- age lower than 4.9 V or higher than 5.1 V.Analogue controls in the cab not working (mini-wheel/joystick, control lever and controls for air condition- ing).Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K4:5, K5:11,K5:13,K7:2, K 9:7, K10:3CAN/ POWER,menu 611.5.3.1Control unit cab
33No feedback signal for control breaker voltage from Relay control breaker voltage (K3009- 1).Control breaker cannot be disengaged. All hydraulic functions are blocked.Check fuse F58-3/8.Check cable harness between the control unit and the component with diagnostic menu.D790-1/ K11:13 – K3009-1/ 87CAN/ POWER,menu 511.5.1.4Control breaker voltage (15E)
34Incorrect signal from Switch parking brake (S107), indicates re- leased and applied at same time or not at all.Parking brake cannot be re- leased.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D791-1/ K8:5 – S107/7D791-1/ K8:13 – S107/1HYD,menu 54.5 Parking brake
35Interference during soft- ware download. Buffer for error codes from Control unit transmission (D793), active error code when downloading.Error code is stored in Control unit transmission (D793).Turn the ignition off and on.Repeat software down- load.D793TRANSM,menu 1311.5.3.9Control unit transmission
36
37
38
39
40
41The transistor has been triggered due to short- circuiting in the circuit to Wiper motor, rear (M650-2).Windshield wiper rear not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K2:4 – M650-2/53CAB,menu 39.5.7 Wiper motor rear
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
42The transistor has been triggered due to short- circuiting in the circuit to Rotating beacon (H428).Rotating beacon not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K2:5 – H428LIGHTS,menu 99.6.8 Ro- tating beacon
43The transistor has been triggered due to short- circuiting in the circuit to Work light cab left (E404-1L).Work light cab left not working.Check the light.Check cable harness between the control unit and the component with diagnostic menu.D790-1/ K2:6 – E404-1LLIGHTS,menu 19.6.9 Work lights cab
44The transistor has been triggered due to short- circuiting in the circuit to Work light cab right (E404-1R).Work light cab right not working.Check the light.Check cable harness between the control unit and the component with diagnostic menu.D790-1/ K2:7 – E404-1RLIGHTS,menu 19.6.9 Work lights cab
45The transistor has been triggered due to short- circuiting in the circuit to Wiper motor, front (M650-1).Windshield wiper front not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K2:1 – M650-1/53CAB,menu 29.5.1 Wiper front
46The transistor has been triggered due to short- circuiting in the circuit to Fan motor (M657-1).Cab fan not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K2:2 – M657-1/2CLI- MATE,menu 69.4.3 Cab fan
47The transistor has been triggered due to short- circuiting in the circuit to Actuator recirculation (M612).The recirculation damper for ventilation is not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K2:3 – M612/3CLI- MATE,menu 69.4.2 Fresh air and re- circulation damper
48The transistor has been triggered due to short- circuiting in the circuit to Water valve (Y673).Heat in cab cannot be adjusted.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K4:1 – Y673/5CLI- MATE,menu 79.4.5 Water valve
49The transistor has been triggered due to short- circuiting in the circuit to Water valve (Y673).Heat in cab cannot be adjusted.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K4:2 – Y673/6CLI- MATE,menu 79.4.5 Water valve
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
50The transistor has been triggered due to short- circuiting in the circuit to Damper motor (Y672)Air distribution in cab cannot be adjusted.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K4:3 – Y672/5CLI- MATE,menu 89.4.14 Air distributor
51The transistor has been triggered due to short- circuiting in the circuit to Damper motor (Y672).Air distribution in cab cannot be adjusted.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K4:4 – Y672/6CLI- MATE,menu 89.4.14 Air distributor
53The transistor has been triggered due to short- circuiting in the circuit to Washer motor roof and rear (M651-2).Windshield washer rear and roof not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K5:4 – M651-2CAB,menu 19.5.4Washer motor and reservoir
54The transistor has been triggered due to short- circuiting or open circuit in the circuit to Switch flashing hazard lights (S109).Flashing hazard lights not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K5:5 – S109/LIGHTS,menu 79.6.7Flashing hazard lights
55The transistor has been triggered due to short- circuiting in the circuit to background lighting in switches and instruments.Reduced or no background lighting in switches and instrumentsCheck bulbs for back- ground lighting, change if needed.Check cable harness to background lighting.D7901/ K6:1, K 8:15, K 9:2,K 10:5, all inputs type A Digital inLIGHTS,menu 139.1 Controls and instruments
56The transistor has been triggered due to short- circuiting or open circuit in the circuit to LED-indication for tilt lock in control lever (S815).Indication for tilt lock in control lever is not illuminated.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:8 – S815/57.1.1 Control lever
57The transistor has been triggered due to short- circuiting or open circuit in the circuit to LED-indication for levelling lock in control lever (S815).Indication for levelling lock in control lever is not illuminated.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:9 – S815/77.1.1 Control lever
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
60The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay seat heater (K383).Seat heater not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:7 – K383/86CAB,menu 89.3.3 Heating coils
61The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay extra work light boom (K304).Extra work light boom not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:8 – K304/86LIGHTS,menu 39.6.10Work light boom
62The transistor has been triggered due to short- circuiting or open circuit in the circuit to simulated D+ feed to hour meter (P708) and Relay compressor air-sus- pended seat (K358).Hour meter and air-suspended seat not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:9 – P708, K358/86CAN/ POWER,menu 79.3.5 Air suspension
63The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay ignition voltage (K315-1).No ignition volt- age to the ma- chine’s Control units.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:10 – K315-1/86CAN/ POWER,menu 411.5.1.3 Ignition volt- age (15)
64The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay control breaker voltage (K3009-1).No control breaker voltage to the machine’s Control units.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:11 – K3009-1/ 86CAN/ POWER,menu 511.5.1.4Control breaker voltage
65The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay control breaker voltage (K3009-2).No control breaker voltage to the machine’s Control units.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:11 – K3009-1/ 86CAN/ POWER,menu 511.5.1.4Control breaker voltage
66The transistor has been triggered due to short- circuiting in the circuit to Washer motor wind- shield (M651-1).Windshield washer not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:13 – M651-1CAB,menu 19.5.4Washer motor and reservoir
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
67The transistor has been triggered due to short- circuiting or open circuit in the circuit to Wiper motor, roof (M650-3).Wiper roof not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K10:14 – M650-3/53CAB,menu 49.5.6 Wiper motor roof
68The transistor has been triggered due to short- circuiting or open circuit in the circuit to Circulation pump pause heater (M667).Pause heater not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K10:15 – M6679.4 Heating, ventilation and air conditioning
69The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay ignition voltage drivetrain (K315-2).No voltage feed to engine and transmission.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K10:16 – K315-2/86CAN/ POWER,menu 411.5.1.3 Ignition voltage (15)
71The transistor has been triggered due to short- circuiting in the circuit to Interior lighting cab (E434-1).Interior lighting in cab not working.Check the light.Check cable harness between the control unit and the component with diagnostic menu.D790-1/ K11:6 – E434-1LIGHTS,menu 129.6.12 Interior lighting cab
74The transistor has been triggered due to short- circuiting in the circuit to Horn (H850) or Relay compressed air horn (K3016)Horn / com- pressed air horn not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K11:11 – H850/1, K3016/86CAB,menu 59.7.1 Horn
75Relay ignition voltage (K315-1) has jammed in position on.Control unit cab (D790-1) is still supplied with voltage and thus active.Check cable harness between the control unit and the component with diagnostic menu.Check the component.CAN/ POWER,menu 411.5.1.3 Ignition volt- age
80No signal from Pressure switch air conditioning (S246), despite the AC compressor being activated.Air conditioning not working.Check drive belt for air conditioning compressor.Check that compressor for air conditioning is activated.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:37 – S246CLI- MATE,menu 39.4.10Pressure monitor
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
81Incorrect signal from- Damper motor (Y672). Signal voltage lower than 0.2 V or higher than4.8 V.Air distribution cannot be changed.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K4:7 – Y672/9CLI- MATE,menu 49.4.6 Fresh air and re- circulation damper
85Incorrect signal from accelerator pedal (R690). Signal voltage lower than 0.2 V or higher than4.8 V.Engine rpm limit- ed to idle.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D790-1/ K6:11 – R690/2ENGINE,menu 11 Engine
87Incorrect signal from Control lever (S815-P1) for lift and lower. Signal voltage lower than 0.2 V or higher than 4.8 V.Lift and lower not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:3 – S815-P1/8BOOM,menu 17.1.1 Control lever
88Incorrect signal from Control lever (S815-P2) for extension. Signal voltage lower than 0.2 V or higher than 4.8 V.Extension not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:4 – S815-P2/4BOOM,menu 17.1.1 Control lever
89Incorrect signal from Control lever (S815-P3) for rotation. Signal volt- age lower than 0.2 V or higher than 4.8 V.Rotation not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:5 – S815-P3/ 11ATTACH,menu 17.1.1 Control lever
90Incorrect signal from Control lever (S815-P4) for tilt. Signal voltage lower than 0.2 V or high- er than 4.8 V.Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K7:6 – S815-P4/1ATTACH,menu 17.1.1 Control lever
92Incorrect signal from Joystick (R825-1) or Mini-wheel (R825-1). Signal voltage lower than 0.2 V or higher than4.8 V.Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K9:8 – R825-1/P2STEER- ING,menu 15.1.2  Mini- wheel5.1.3  Joy- stick
93Incorrect signal from Mini-wheel (R825-2). Signal voltage lower than 0.2 V or higher than4.8 V.Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the switch.D790-1/ K9:9 – R825-2/H2STEER- ING,menu 15.1.2 Mini- wheel
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
94Incorrect signal from Water valve cab heat (Y673). Signal voltage lower than 0.2 V or higher than 4.8 V.Cab heat cannot be adjusted.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D790-1/ K10:4 – Y673/9CLI- MATE,menu 49.4.5 Water valve
96Incorrect signal from Sensor cab temperature (B775-1). The sensor indicates temperature be- low -43 °C or above 105° C.Air conditioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D790-1/ K4:8 – B775-1/2CLI- MATE,menu 19.4.17 Sensor cab temperature
97Incorrect signal from Sensor outdoor temperature (B774). Temperature signal above 105° C.Air conditioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D790-1/ K4:9 – B774/2CLI- MATE,menu 29.4.18 Sensor out- door temperature
98Incorrect signal from Sensor temperature outlet fan (B775-2). The sensor indicates temperature below -43 °C or above 105 °C.Air conditioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D790-1/ K4:10 – B775-2/2CLI- MATE,menu 29.4.16 Sensor temperature outlet fan
99Incorrect signal from Sensor temperature refrigerant (B775-3). The sensor indicates temperature below -43 °C or above 105 °C.Air conditioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D790-1/ K4:11 – B775-3/2CLI- MATE,menu 29.4.12 Sensor temperature refrigerant
101Redundant voltage feed left to Control unit frame front (D797-F) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-F/ K2:7CAN/ POWER,menu 811.5.1.2Redundant voltage feed of Control units
102Redundant voltage feed right to Control unit frame front (D797-F) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-F/ K2:8CAN/ POWER,menu 811.5.1.2Redundant voltage feed of Control units
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
103Incorrect electric power feed to Control unit frame front (D797-F). Voltage lower than 18 V or higher than 32 V.No electric power feed to components.Check fuse F58-2/1, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K2:1, K2:9, K2:10 – F58-2/1:1, 1:2CAN/ POWER,menu 811.5.1.3 Ignition volt- age (15)
104Incorrect control break- er voltage to Control unit frame front (D797-F).Functions sup- plied with control breaker voltage have no feed. All hydraulic functions are blocked.Check fuse F58-3/2, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K2:11 – F58-3/2:1CAN/ POWER,menu 811.5.1.4Control breaker voltage
105Incorrect 5 V reference voltage to pressure sensor. Voltage lower than4.9 V or higher than 5.1 V.Regeneration lift, weight indicator and over- load system not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:8 – B768-R1/1, B768-R2/1, B768-L1/1, B768-L2/1CAN/ POWER,menu 98.2.1.7Sensor hydraulic pressure lift cylinder
106The transistor has been triggered due to short- circuiting in the circuit to Cooling fan, brake oil (M674).Cooling fan brake oil not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D797-F/ K1:14 – M674/1HYD,menu 24.8.8 Cooling fan
107The transistor has been triggered due to short- circuiting or open circuit in the circuit to High beam light left (E402L).Left high beam not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:1 – E402L/1LIGHTS,menu 69.6.1Headlights
108The transistor has been triggered due to short- circuiting or open circuit in the circuit to High beam light right (E402R).Right high beam not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:15 – E402R/1LIGHTS,menu 69.6.1Headlights
110The transistor has been triggered due to short- circuiting or open circuit in the circuit to Low beam light (E400L/ E400R).Low beams not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:42 – E400L/1, E400R/1LIGHTS,menu 69.6.1Headlights
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
111The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve boom up (Y6005).Lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:2 – Y6005/1BOOM,menu 47.2.5 Control valve lift, lower and extension
112The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve boom down (Y6004).Lower not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:3 – Y6004/1BOOM,menu 57.2.5 Control valve lift, lower and extension
113The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve boom out (Y6006).Extension out not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:4 – Y6006/1BOOM,menu 77.3.5 Control valve lift, lower and extension
114The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve boom in (Y6007).Extension in not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:5 – Y6007/1BOOM,menu 67.3.5 Control valve lift, lower and extension
115The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve blocking lift left (Y6002).Lift and lower not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:30 – Y6002/1BOOM,menu 27.2.7 Valve block lift cylinder
116The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve blocking lift right (Y6001).Lift and lower not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:31 – Y6001/1BOOM,menu 27.2.7 Valve block lift cylinder
117The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve regeneration lift right (Y6051).Regenerating lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:32 – Y6051/1BOOM,menu 37.2.7 Valve block lift cylinder
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
118The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve regeneration lift left (Y6052).Regenerating lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:33 – Y6052/1BOOM,menu 37.2.7 Valve block lift cylinder
119The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve parking brake (Y642).Parking brake cannot be re- leased.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:7 – Y642/1HYD,menu 54.5.3 Solenoid valve parking brake
120The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb direction indicator left front (H422).Direction indicator left front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:9 – H422/1LIGHTS,menu 89.6.6 Direction indicators
121The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb direction indicator right front (H423).Direction indicator right front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:10 – H423/1LIGHTS,menu 89.6.6 Direction indicators
122The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb running light left front H416-1).Running light left front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:25 – H416-1/1LIGHTS,menu 59.6.2 Running lights
123The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb running light right front (H417-1).Running light right front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K1:29 – H417-1/1LIGHTS,menu 59.6.2 Running lights
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
124Incorrect 24 V reference voltage to Break-contact parking brake (S200), Break-contact low brake pressure (S204), Make- contact brake lights (S216) and Break-contact declutch (S220-2).Indicator light parking brake and warning for low brake pressure do not go off. Brake lights and declutch not working. Gear cannot be engaged since the signal for re- leased parking brake is not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:39 – S200/1, S204/1, S216/1, S220/1CAN/ POWER,menu 94.5.5Break-con- tact parking brake4.3.8Make-con- tact brake lights4.3.7Break-con- tact brake pressure
133Incorrect signal from Sensor hydraulic pressure lift cylinder left (B768-L1). Signal volt- age lower than 0.2 V or higher than 4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:21 – B768-L1/3OP, menu 3 [V]HYD,menu 6 [bar]7.2.9 Sen- sor hydraulic pressure lift cylinder
134Incorrect signal from Sensor hydraulic pressure lift cylinder left (B768-L2). Signal volt- age lower than 0.2 V or higher than 4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:22 – B768-L2/3OP, menu 3 [V]HYD,menu 6 [bar]7.2.9 Sensor hydraulic pressure lift cylinder
135Incorrect signal from Sensor hydraulic pressure lift cylinder right (B768-R1). Signal volt- age lower than 0.2 V or higher than 4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:23 – B768-R1/3OP, menu 3 [V]HYD,menu 6 [bar]7.2.9 Sensor hydraulic pressure lift cylinder
136Incorrect signal from Sensor hydraulic pressure lift cylinder right (B768-R2). Signal volt- age lower than 0.2 V or higher than 4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-F/ K1:24 – B768-R2/3OP, menu 3 [V]HYD,menu 6 [bar]7.2.9 Sensor hydraulic pressure lift cylinder
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
137Incorrect signal from Solenoid valve boom up (Y6005). The return cur- rent does not match the control current.Lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:16 – Y6005/2BOOM,menu 47.2.5 Control valve lift, lower and extension
138Incorrect signal from Solenoid valve boom down (Y6004). The return cur- rent does not match the control current.Lower not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:17 – Y6004/2BOOM,menu 57.2.5 Control valve lift, lower and extension
139Incorrect signal from Solenoid valve boom out (Y6006). The return current does not match the control current.Extension out not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:18 – Y6006/2BOOM,menu 77.3.5 Control valve lift, lower and extension
140Incorrect signal from Solenoid valve boom in (Y6007). The return cur- rent does not match the control current.Extension in not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-F/ K1:19 – Y6007/2BOOM,menu 67.3.5 Control valve lift, lower and extension
145Incorrect signal from Sensor boom angle (B771). Logic error, signal does not change when lift or lower is activated.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check sensor arm’s attachment.Check the sensor.Check cable harness between the control unit and the component with diagnostic menu.OP, menu 48.2.1.5Sensor boom angle
146Incorrect signal from Sensor boom length (B777). Logic error, signal does not change when extension is activated.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check the line to the sensor.Check the sensor.Check cable harness between the control unit and the component with diagnostic menu.OP, menu 48.2.1.6Sensor boom length
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
147High brake oil temperature.Reduced braking capacity.Check that cooling fan is working.Check that cooler isn’t clogged.Check the sensor.D797-F/ K2:13 – B762/1HYD,menu 24.8 Temperature control, cleaning and brake oil
148Incorrect signal from Sensor brake oil temperature (B762). Signal voltage lower than 0.2 V or higher than 4.8 V.Check the sensor.Check cable harness between the control unit and the component with diagnostic menu.D797-F/ K2:13 – B762/1HYD,menu 24.8.10 Sensor brake oil temperature
149Incorrect load curve or load curve missing.Lift, lower and extension not working.Contact Kalmar Indus- tries AB.7.2 Lift and lower. 7.3 Extension
150Defective overload protection.This error code cannot be removed with Reset.Overload system not working. All lift functions operate with reduced speed.Check if there are error codes for sensors in the overload system.OP, menu 1 – 58.2.1 Over- load system
151Redundant voltage feed left to Control unit frame rear (D797-R) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-R/ K2:7CAN/ POWER,menu 1011.5.1.2Redundant voltage feed of Control units
152Redundant voltage feed right to Control unit frame rear (D797-R) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-R/ K2:8CAN/ POWER,menu 1011.5.1.2Redundant voltage feed of Control units
153Incorrect electric power feed to Control unit frame rear (D797-R). Voltage lower than 18 V or higher than 32 V.Check fuse F58-2/3, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K2:1, K2:9, K2:10 – F58-2/3:1CAN/ POWER,menu 1011.5.1.3 Ignition volt- age (15)
154Incorrect electric power feed to Control unit frame rear (D797-R).Check fuse F58-2/3, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K2:11 – F58-2/3:2CAN/ POWER,menu 1011.5.1.4Control breaker voltage
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
155Incorrect 5 V reference voltage to analogue sensor. Voltage lower than 4.9 V or higher than5.1 V.Overload system and weight indicator not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-R/ K1:8 – B771/1, B777/1CAN/ POWER,menu 118.2.1.5Sensor boom angle8.2.1.6Sensor boom length (analogue sensor)
156The transistor has been triggered due to short- circuiting in the circuit to Cooling fan hydraulic oil (M668).Cooling fan hydraulic oil not working.Check cable harness between the control unit and the component with diagnostic menu.Check the motor.D797-R/ K1:14 – M668/1HYD,menu 110.6.3Cooling fan
157The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb work light boom left (E404-3L).Work light boom left not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:1 – E404-3LLIGHTS,menu 39.6.10Work light boom
158The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb work light boom right (E404-3R).Work light boom right not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:15 – E404-3RLIGHTS,menu 39.6.10Work light boom
159The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb back-up light left (E405L).Back-up light left not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:28 – E405LLIGHTS,menu 119.6.5 Back- up light
160The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb back-up light right (E405R).Back-up light right not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:42 – E405RLIGHTS,menu 119.6.5 Back- up light
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
161The transistor has been triggered due to short- circuiting or open circuit in the circuit to Sensor steering axle load (B7221L and b7221R).Overload system indicates overload.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-R/ K1:2 – B7221L/A, B7221R/AOP, menu 18.2.1.4Sensor steering axle load
162The transistor has been triggered due to short- circuiting or open circuit in the circuit to Sensor position sensor boom lengthDamping in/out/ 1.5m not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-R/ K1:2 – B777/A, B769-3/A, B769-4/AOP, menu 1BOOM,menu 88.2.1.6Sensor boom length description (position sensor)
163The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve regeneration ex- tension (Y6046).Regeneration extension not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-R/ K1:4 – Y6046/1BOOM,menu 37.3.7 Valve block ex- tension cylinder
164The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve blocking extension (Y6050).Extension not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-R/ K1:5 – Y6050/1BOOM,menu 27.3.7 Valve block ex- tension cylinder
165The transistor has been triggered due to short- circuiting or open circuit in the circuit to Back-up warning (H965).Back-up alarm not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D797-R/ K1:30 – H965/1LIGHTS,menu 119.7.5 Back- up alarm
166The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve top hydraulics (Y6003).Attachment functions not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-R/ K1:31 – Y6003/1HYD,menu 67.4.2 Valve block top lift hydraulics
167The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb brake light left (H411L).Brake light left not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:32 – H411L/1LIGHTS,menu 119.6.4 Brake lights
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
168The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb brake light right (H411R).Brake light right not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:33 – H411R/1LIGHTS,menu 119.6.4 Brake lights
169The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb running light left (H416-2).Running light left rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:7 – H416-2/1LIGHTS,menu 59.6.2 Running lights
170The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb running light right (H417-2).Running light right rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:9 – H417-2/1LIGHTS,menu 59.6.2 Running lights
171The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb rear light left (H421L).Rear light left not working.Check the light.Check the bulb holder. Check the bulb holder.D797-R/ K1:10 – H412L/1LIGHTS,menu 59.6.3 Rear lights
172The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb rear light right (H421R).Rear light left not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:25 – H412R/1LIGHTS,menu 59.6.3 Rear lights
173The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb direction indicator left rear (H426).Direction indicator left rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:29 – H426/1LIGHTS,menu 89.6.6 Direction indicators
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
174The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb direction indicator right rear (H426).Direction indicator right rear not working.Check the  light. Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K1:39 – H427/1LIGHTS,menu 89.6.6 Direction indicators
175Different signal from Sensor steering axle load (B7221L and B722R) for more than 10 seconds.Overload system indicates overload.Check sensor’s adjustment.Check the sensor.D797-R/ K1:11 – B7221L/CD797-R/ K1:12 – B7221R/COP, menu 18.2.1.4Sensor steering axle load
178The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve pump unloading (Y6062).Unloading of hydraulic oil pumps at boom in not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-R/ K1:40 – Y6062/1BOOM,menu 27.3.8 Valve block pump unloading
183Incorrect signal from Sensor boom angle (771). Signal voltage lower than 0.2 V or high- er than 4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-R/ K1:21 – B771/3OP, menu 48.2.1.5Sensor boom angle
184Incorrect signal from Sensor length (777). Signal voltage lower than 0.2 V or higher than4.8 V.Overload system not working. All lift functions operate with reduced speed.Error code 150 is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-R/ K1:22 – B777/3OP, menu 48.2.1.6Sensor boom length
191The transistor has been triggered due to short- circuiting or open circuit in the circuit to Magnetic clutch on AC compressor (M677).NOTE! Error code 191 and 192 here go to the same user.Air conditioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D797-R/ K1:11 – M645/1CLI- MATE,menu 69.4.8 Com- pressor
192D797-R/ K1:26 – M645/1
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
193Only engine alternative Cummins QSM11:The transistor has been triggered due to short- circuiting or open circuit in the circuit to Relay starter motor (K360).Starter motor not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D797-R/ K1:36 – K360/86ENGINE,menu 51 Engine
197High temperature hydraulic oil.No limitation.Check that cooling fan is working.Check that cooler isn’t clogged.Check the sensor.D797-R/ K2:13 – B776/1HYD,menu 110.6 Temperature control, cleaning and hydraulic oil
198Incorrect signal from- Sensor hydraulic oil temperature (B776).Incorrect temperature display.Check the sensor.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K2:13 – B776/1HYD,menu 110.6.4 Sensor hydraulic oil temperature
199Incorrect signal from Sensor fuel level (B757). Resistance higher than 180 Ù.Incorrect dis- play of fuel amount (empty or full).Check the sensor.Check cable harness between the control unit and the component with diagnostic menu.D797-R/ K2:15 – B757CAB,menu 71.2.2 Sensor fuel level
201Redundant voltage feed left to Control unit frame option (D797-O) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-O/ K2:7CAN/ POWER,menu 1211.5.1.2Redundant voltage feed of Control units
202Redundant voltage feed right to Control unit frame option (D797-O) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D797-O/ K2:8CAN/ POWER,menu 1211.5.1.2Redundant voltage feed of Control units
203Incorrect electric power feed to Control unit frame option (D797-O). Voltage lower than 18 V or higher than 32 V.Check fuse F58-2/4, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-O/ K2:10 – F58-2/4:1CAN/ POWER,menu 1211.5.1.3 Ignition voltage (15)
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
204Incorrect control breaker voltage to Control unit frame option (D797-O).Functions sup- plied with control breaker voltage have no feed. All hydraulic functions are blocked.Check fuse F58-3/4, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D797-O/ K2:11 – F58-3/4:1CAN/ POWER,menu 1211.5.1.4Control breaker voltage
211The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve cab front/up (Y6016).Hydraulic sliding cab or cab lift not workingCheck cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:2 – Y6016/1SLIDING CAB,menu 39.10.4.3Control valve option frame9.10.5.2Control valve op- tion frame
212The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve cab rear/ down (Y6017).Hydraulic sliding cab or cab lift not workingCheck cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:3 – Y6017/1SLIDING CAB,menu 49.10.4.3Control valve option frame9.10.5.2Control valve option frame
213The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve steering left (Y636L).Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:4 – Y636L1/1EL- STEERING,menu 45.2.10Control valve joy- stick steering/mini- wheel
214The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve steering right (Y636R).Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:5 – Y636R1/1ELSTEER- ING,menu 55.2.10Control valve joystick steering/mini- wheel
215The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve support jacks up (Y6053).Support jacks not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:30 – Y6063/1SUP-PORT JACKS,menu 37.10.1.2Control valve option frame
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
216The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve support jacks down (Y6064).Support jacks not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:31 – Y6064/1SUP- PORT JACKS,menu 37.10.1.2Control valve option frame
217Solenoid valve cab tilt up (Y6047).Cab tilt not working.Check cable harness between the control unit and the component withdiagnostic menu.D797-O/ K1:32 – Y6047/1SLIDING CAB,menu 3MISSING
Check the solenoid valve.
218Solenoid valve cab tilt down (Y6048).Cab tilt not working.Check cable harness between the control unit and the component with diagnostic menu.D797-O/ K1:33 – Y6048/1SLIDING CAB,menu 4MISSING
Check the solenoid valve.
219Solenoid valve disengagement of hydraulic oil pumps (Y6057).Disengagement of hydraulic oil pump when lowering til table cab not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:7 – Y6057/1HYD,menu 6MISSING
220Incorrect 24 V reference voltage to Position sensor support jacks (B7222L, B7222R, B7223L and B7223R).Indication sup- port jacks up not working. Gear cannot be selected to operate the machine.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-O/ K1:9 – B7222L, B7222R, B7223L, B7223RSUP- PORT JACKS,menu 27.10.1.5Sensor raised sup- port jacks7.10.1.6Sensor lowered support jacks
221Incorrect 24 V reference voltage to Position sensor cab lift (B777-2).Indication Lowered cab not working. Door must be closed to allow lowering of boom. Speed limitation is activated.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D797-O/ K1:10 – B777-2/1SLIDING CAB,menu 49.10.5.8Sensor lowered cab
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
237Incorrect signal from Solenoid valve cab front/up (Y6016). The return current does not match the control cur- rent.Hydraulic sliding cab or cab lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:16 – Y6016/2SLIDING CAB,menu 39.10.4.3Control valve option frame9.10.5.2Control valve option frame
238Incorrect signal from Solenoid valve cab rear/ down (Y6017). The re- turn current does not match the control cur- rent.Hydraulic sliding cab or cab lift not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:17 – Y6017/2SLIDING CAB,menu 49.10.4.3Control valve option frame9.10.5.2Control valve option frame
239Incorrect signal from Solenoid valve steering left (Y636L). The return current does not match the control current.Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:18 – Y636L/2EL- STEER- ING,menu 45.2.10Control valve joy- stick steer- ing/mini- wheel
240Incorrect signal from Solenoid valve steering right (Y636R). The re- turn current does not match the control cur- rent.Joystick steering or mini-wheel not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D797-O/ K1:19 – Y636R/2EL- STEER- ING,menu 55.2.10Control valve joy- stick steer- ing/mini- wheel
251Redundant voltage feed left to Control unit attachment (D791-1) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K2:7CAN/POWER,menu 1611.5.1.2 Redundant voltage feed of Controlunits
252Redundant voltage feed left to Control unit attachment (D791-1) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K2:8CAN/POWER,menu 1611.5.1.2 Redundant voltage feed of Controlunits
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
253Incorrect electric power feed to Control unit attachment (D791-1).Voltage lower than 18 V or higher than 32 V.Functions sup- plied with control breaker voltage have no feed. No attachment functions working.Check fuse F58-3/1, change if needed.Check fuse F52-1, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K2:1/9/10 – F52-1 – F58-3/1:1CAN/ POWER,menu 1611.5.1.4Control breaker voltage
254Incorrect control breaker voltage to Control unit attachment (D791-1).Functions sup- plied with control breaker voltage have no feed. No attachment functions working.Check fuse F58-3/1, change if needed.Check fuse F52-1, change if needed.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K2:11 – F58-3/1CAN/ POWER,menu 1611.5.1.4Control breaker voltage
257The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb work light attachment right (E406R).Work light attachment right not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:1 – E406RLIGHTS,menu 29.6.11Work light attachment
258The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb work light attachment left (E406L).Work light attachment left not working.Check bulb.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:15 – E406LLIGHTS,menu 29.6.11Work light attachment
259The transistor has been triggered due to short- circuiting or open circuit in the circuit to Buzzer automatic positioning 20’-40’ (H4009).Automatic positioning 20′-40′ not working.Check cable harness between the control unit and the component with diagnostic menu.Check the component.D791-1/ K1:28 – H9003/1ATTACH,menu 157.5Spreading
260The transistor has been triggered due to short- circuiting or open circuit in the circuit to Light bulb extra work light attachment (E404-4L and E404-4R).Extra work light attachment not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:42 – E404-4L, E404-4RLIGHTS,menu 29.6.11Work light attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
261The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve rotation clockwise (Y6008).Rotation of attachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:2 – Y6008/1ATTACH,menu 117.6.3 Control valve attachment
262The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve rotation counter-clockwise (Y6009)Rotation of attachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:3 – Y6009/1ATTACH,menu 127.6.3 Control valve attachment
263The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve positioning out (Y6018).Spreading not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:4 – Y6018/1ATTACH,menu 137.5.3 Control valve attachment
264The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve positioning in (Y6019).Spreading not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:5 – Y6019/1ATTACH,menu 147.5.3 Control valve attachment
265The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve sideshift right (Y6021).Sideshift of attachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:30 – Y6021/1ATTACH,menu 87.4.3 Control valve attachment
266The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve sideshift left (Y6020).Sideshift of attachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:31 – Y6020/1ATTACH,menu 87.4.3 Control valve attachment
267The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve lock twistlock (Y6040).Twistlock not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:32 – Y6040/1ATTACH,menu 97.9.1.3Control valve attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
268The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve open twistlock (Y6039).Twistlock not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:33 – Y6039/1ATTACH,menu 97.9.1.3Control valve attachment
269The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve tilt lock 1 (Y6012- 1).Tilt locked, tilt damping and controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:7 – Y6012-1/1ATTACH,menu 157.7.4 Lock valve tilt
270The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve tilt lock 2 (Y6012- 2).Tilt locked, tilt damping and controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:9 – Y6012-2/1ATTACH,menu 157.7.4 Lock valve tilt
271The transistor has been triggered due to short- circuiting or open circuit in the circuit to Voltage feed Position sensor attachment.Twistlocks, rotation stop, and positioning not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D791-1/ K1:10 – B769/A, B777-2/A, B7225/A, B7202R/A, B7204R/A, B7205R/A, B7203R/A, B7202L/A, B7204L/A, B7205L/A, B7203L/A,B7224/AATTACH,menu 5, 6,7, 217.5.10 Position sensor positioning7.6.10 Sensor rotation stop7.9.1.8Sensor alignment7.9.1.9Sensor twistlocks
8.2.1.6Sensor boom length description (position sensor)
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
272The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light twistlock open (H562).Indicator light open twistlock not working.Check the  light. Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:25 – H562/1ATTACH,menu 107.9.1 Twist- locks
273The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light alignment (H564).Indicator light alignment twist- lock not working.Check the  light. Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:29 – H564/1ATTACH,menu 107.9.1 Twist- locks
274The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light twistlock locked (H563).Indicator light locked twistlock not working.Check the  light. Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-1/ K1:39 – H563/1ATTACH,menu 107.9.1 Twist- locks
287Incorrect signal from Solenoid valve rotation clockwise (Y6008). The return current does not match the control cur- rent.Rotation of at- tachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:16 – Y6008/2ATTACH,menu 117.6.3 Control valve attachment
288Incorrect signal from Solenoid valve rotation counter-clockwise (Y6009). The return cur- rent does not match the control current.Rotation of at- tachment not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:17 – Y6009/2ATTACH,menu 127.6.3 Control valve attachment
289Incorrect signal from Solenoid valve position- ing out (Y6018). The re- turn current does not match the control cur- rent.Spreading not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:18 – Y6018/2ATTACH,menu 137.5.3 Control valve attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
290Incorrect signal from Solenoid valve positioning in (Y6019). The re- turn current does not match the control cur- rent.Spreading not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-1/ K1:19 – Y6019/2ATTACH,menu 147.5.3 Con- trol valve attachment
298Sensor twistlock indicates that left twistlock is between open and locked position.Lift and extension not working.Check that Sensors twistlock are clean and correctly adjusted.Check cable harness between the control unit and the component with diagnostic menu.ATTACH,menu 77.9.1.9Sensor twistlocks
299Sensor twistlock indicates that right twistlock is between open and locked position.Lift and extension not working.Check that Sensors twistlock are clean and correctly adjusted.Check cable harness between the control unit and the component with diagnostic menu.ATTACH,menu 77.9.1.9Sensor twistlocks
300Sensor alignment indicates unreasonable condition.Twistlock not working.Check that Sensors alignment are clean and correctly adjusted.ATTACH,menu 67.9.1.8Sensor alignment
Check that contact pin runs freely.
Check cable harness between the control unit and the component with diagnostic menu.
301Redundant voltage feed left to Control unit attachment option (D791-2) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-2/ K2:7CAN/ POWER,menu 1711.5.1.2Redundant voltage feed of Control units
302Redundant voltage feed left to Control unit attachment option (D791-2) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-2/ K2:8CAN/ POWER,menu 1711.5.1.2Redundant voltage feed of Control units
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
303Incorrect electric power feed to Control unit attachment option (D791- 2). Voltage lower than 18 V or higher than 32 V.Levelling, tilt and special function not working.Check fuse F58-3/1 and F52-1, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-2/ K2:1, K2:9, K2:10 –F52-1 – F58-3/1CAN/ POWER,menu 1711.5.1.4Control breaker voltage
304Incorrect control breaker voltage to Control unit attachment option (D791-2).Functions sup- plied with control breaker voltage have no feed.Levelling, tilt and special function not working.Check fuse F58-3/1 and F52-1, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-2/ K2:11 –F52-1 – F58-3/1CAN/ POWER,menu 1711.5.1.4Control breaker voltage
311The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve levelling right (Y6035).Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:2 – Y6035/1ATTACH,menu 197.8.3 Control valve attachment
312The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve levelling left (Y6036).Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:3 – Y6036/1ATTACH,menu 207.8.3 Control valve attachment
313The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve tilt out (Y6010).Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:4 – Y6010/1ATTACH,menu 167.7.5 Control valve attachment
314The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve tilt in (Y6011).Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:5 – Y6011/1ATTACH,menu 177.7.5 Control valve attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
315The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve levelling lock (Y6034-1).Levelling is locked, controllable levelling and float mode not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:30 – Y6034-1/1ATTACH,menu 187.8.6 Valve block level- ling cylinders
316The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve levelling lock (Y6034-2).Levelling is locked, controllable levelling and float mode not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:31 – Y6034-2/1ATTACH,menu 187.8.6 Valve block level- ling cylinders
317Incorrect output signal special function.WARNINGD791-2/ K1:32
318Incorrect output signal special function.WARNINGD791-2/ K1:33
319Incorrect output signal special function.WARNINGD791-2/ K1:7
320Incorrect output signal special function.WARNINGD791-2/ K1:9
321Incorrect output signal special function.WARNINGD791-2/ K1:10
322Incorrect output signal special function.WARNINGD791-2/ K1:25
337Incorrect signal from Solenoid valve levelling right (Y6035). The re- turn current does not match the control cur- rent.Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:16 – Y6035/2ATTACH,menu 177.8.3 Control valve attachment
338Incorrect signal from Solenoid valve levelling left (Y6036). The return current does not match the control current.Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:17 – Y6036/2ATTACH,menu 187.8.3 Control valve attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
339Incorrect signal from Solenoid valve tilt out (Y6010). The return cur- rent does not match the control current.Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:18 – Y6010/2ATTACH,menu 147.7.5 Control valve attachment
340Incorrect signal from Solenoid valve tilt in (Y6011). The return cur- rent does not match the control current.Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-2/ K1:19 – Y6011/2ATTACH,menu 157.7.5 Control valve attachment
351Redundant voltage feed left to Control unit attachment left legs (D791-3) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-3/ K2:7CAN/ POWER,menu 1811.5.1.2Redundant voltage feed of Control units
352Redundant voltage feed right to Control unit attachment left legs (D791-3) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-3/ K2:8CAN/ POWER,menu 1811.5.1.2Redundant voltage feed of Control units
353Incorrect electric power feed to Control unit attachment left legs (D791-3). Voltage lower than 18 V or higher than 32 V.Left lift leg not working.Check fuse F58-3/1 and F52-2, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K2:1 –F52-2 – F58-3/1CAN/ POWER,menu 1811.5.1.4Control breaker voltage
354Incorrect control breaker voltage to Control unit attachment left legs (D791-3).Functions sup- plied with control breaker voltage have no feed.Left lift leg not working.Check fuse F58-3/1 and F52-2, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K2:11 –F52-2 – F58-3/1CAN/ POWER,menu 1811.5.1.4Control breaker voltage
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
357The transistor has been triggered due to short- circuiting or open circuit in the circuit to Work light left lift leg (E404- 6L).Work light left lift leg not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K1:1 – E404-6L/19.6.11Work light attachment
358The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve levelling lock (Y6034-1) and Solenoid valve levelling lock (Y6034-2).Levelling is locked, controllable levelling and float mode not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:15 – Y6034-1/1, Y6034-2/1ATTACH,menu 187.8.6 Valve block level- ling cylinders
360The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve operating position (Y6053L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:42 – Y6053L/1COMBI,menu 167.9.2.5Valve operating position
361The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve levelling right (Y6035).Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:2 – Y6035/1ATTACH,menu 197.8.3 Control valve attachment
362The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve levelling left (Y6036).Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:3 – Y6036/1ATTACH,menu 207.8.3 Control valve attachment
363The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front knee in (Y6057L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:4 – Y6057L/1COMBI,menu 117.9.2.3Control valve lift legs
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
364The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front knee out (Y6056L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:5 – Y6056L/1COMBI,menu 107.9.2.3Control valve lift legs
365The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve rear knee in (Y6059L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:30 – Y6059L/1COMBI,menu 137.9.2.3Control valve lift legs
366The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve rear knee out (Y6058L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:31 – Y6058L/1COMBI,menu 127.9.2.3Control valve lift legs
367The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve lowering front leg (Y6013L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:32 – Y6013L/1COMBI,menu 107.9.2.3Control valve lift legs
368The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front leg up (Y6060L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:33 – Y6060L/1COMBI,menu 117.9.2.3Control valve lift legs
369The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve lowering rear leg (Y6014L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:7 – Y6014L/1COMBI,menu 127.9.2.3Control valve lift legs
370The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve rear leg up (Y6061L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:9 – Y6061L/1COMBI,menu 137.9.2.3Control valve lift legs
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
371The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H566R).Indicator light alignment lift leg right front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K1:10 – H566R/1COMBI,menu 77.9.2 Lift legs
372The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H567R).Indicator light alignment lift leg right rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K1:25 – H567R/1COMBI,menu 77.9.2 Lift legs
373The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H556L).Indicator light alignment lift leg left front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K1:29 – H566L/1COMBI,menu 77.9.2 Lift legs
374The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H556L).Indicator light alignment lift leg left rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-3/ K1:39 – H567L/1COMBI,menu 77.9.2 Lift legs
375The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve clamp shut (Y6054L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:11 – Y6054L/1COMBI,menu 157.9.2.3Control valve lift legs
376The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve clamp open (Y6055L).Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:12 – Y6055L/1COMBI,menu 157.9.2.3Control valve lift legs
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
377The transistor has been triggered due to short- circuiting or open circuit in the circuit to voltage feed position sensor left leg pair.Left lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D791-3/ K1:26 – B7212L/A, B7213L/A, B7214L/A, B7215L/A, B7216L/A, B7217L/A, B7218L/A, B7219L/A,B7220L/ACOMBI,menu 2, 3,4, 5, 67.9.2.9Sensor operating position7.9.2.10Sensor knee7.9.2.13Sensor lift leg
7.9.2.15Sensor alignment
7.9.2.16Sensor clamping position
387Incorrect signal from Solenoid valve levelling right (Y6035). The re- turn current does not match the control cur- rent.Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:16 – Y6035/2ATTACH,menu 197.8.3 Con- trol valve attachment
388Incorrect signal from Solenoid valve levelling left (Y6036). The return current does not match the control current.Levelling not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-3/ K1:17 – Y6036/2ATTACH,menu 207.8.3 Control valve attachment
401Redundant voltage feed left to Control unit attachment right leg pair (D791-4) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-4/ K2:7CAN/ POWER,menu 1911.5.1.2Redundant voltage feed of Control units
402Redundant voltage feed right to Control unit attachment right leg pair (D791-4) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.Check the control unit.D791-4/ K2:8CAN/ POWER,menu 1911.5.1.2Redundant voltage feed of Control units
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
403Incorrect electric power feed to Control unit attachment right leg pair (D791-4). Voltage lower than 18 V or higher than 32 V.Right lift leg and controllable tilt not working.Check fuse F58-3/1 and F52-2, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K2:1 –F52-2 – F58-3/1CAN/ POWER,menu 1911.5.1.4Control breaker voltage
404Incorrect control breaker voltage to Control unit attachment right leg pair (D791-4).Control breaker cannot be disengaged. Right lift leg and controllable tilt not working.Check fuse F58-3/1 and F52-2, change if need- ed.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K2:11 –F52-2 – F58-3/1CAN/ POWER,menu 1911.5.1.4Control breaker voltage
407The transistor has been triggered due to short- circuiting or open circuit in the circuit to Work light left lift leg (E404- 6R).Work light left lift leg not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K1:1 – E404-6R9.1.11Work light attachment
410The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve operating position (Y6053R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:42 – Y6053R/1COMBI,menu 167.9.2.5Valve operating position
411The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve tilt out (Y6010).Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:15 – Y6010/1ATTACH,menu 167.7.5 Control valve attachment
412The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve tilt in (Y6010).Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:15 – Y6011/1ATTACH,menu 177.7.5 Control valve attachment
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
413The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front knee in (Y6057R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:4 – Y6057R/1COMBI,menu 117.9.2.3Control valve lift legs
414The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front knee out (Y6056R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:5 – Y6056R/1COMBI,menu 107.9.2.3Control valve lift legs
415The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve rear knee in (Y6059R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:30 – Y6059R/1COMBI,menu 137.9.2.3Control valve lift legs
416The transistor has been triggered due to short- circuiting in the circuit to Solenoid valve rear knee out (Y6058L).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:31 – Y6058R/1COMBI,menu 127.9.2.3Control valve lift legs
417The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve lowering front leg (Y6013R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:32 – Y6013R/1COMBI,menu 107.9.2.3Control valve lift legs
418The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve front leg up (Y6060R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:33 – Y6060R/1COMBI,menu 117.9.2.3Control valve lift legs
419The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve lowering rear leg (Y6014R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:7 – Y6014R/1COMBI,menu 127.9.2.3Control valve lift legs
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
420The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve rear leg up (Y6061R).Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:9 – Y6061R/1COMBI,menu 137.9.2.3Control valve lift legs
421The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H580).Indicator light front legs raised not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K1:10 – H580/1COMBI,menu 97.9.2 Lift legs
422The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H581).Indicator light front legs low- ered not work- ing.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K1:25 – H581/1COMBI,menu 97.9.2 Lift legs
423The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H578).Indicator light clamping position lift legs front not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K1:29 – H578/1COMBI,menu 87.9.2 Lift legs
424The transistor has been triggered due to short- circuiting or open circuit in the circuit to Indicator light (H579).Indicator light clamping position lift legs rear not working.Check the light.Check the bulb holder.Check cable harness between the control unit and the component with diagnostic menu.D791-4/ K1:39 – H579/1COMBI,menu 87.9.2 Lift legs
425The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve clamp shut (Y6054R).Right lift leg not working.D791-4/ K1:2 – Y6054RCOMBI,menu 157.9.2.3Control valve lift legs
426The transistor has been triggered due to short- circuiting or open circuit in the circuit to Solenoid valve clamp open (Y6055R).Right lift leg not working.D791-4/ K1:3 – Y6055RCOMBI,menu 157.9.2.3Control valve lift legs
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
427The transistor has been triggered due to short- circuiting or open circuit in the circuit to Voltage feed position sensor right leg pair.Right lift leg not working.Check cable harness between the control unit and the component with diagnostic menu.Check the sensor.D791-4/ K1:26 – B7212R/A, B7213R/A, B7214R/A, B7215R/A, B7216R/A, B7217R/A, B7218R/A, B7219R/A,B7220R/ACOMBI,menu 2, 3,4, 5, 67.9.2.9Sensor operating position7.9.2.10Sensor knee7.9.2.13Sensor lift leg
7.9.2.15Sensor alignment
7.9.2.16Sensor clamping position
437Incorrect signal from Solenoid valve tilt out (Y6010). The return cur- rent does not match the control current.Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:16 – Y6010/2ATTACH,menu 167.7.5 Control valve attachment
438Incorrect signal from Solenoid valve tilt in (Y6010). The return cur- rent does not match the control current.Controllable tilt not working.Check cable harness between the control unit and the component with diagnostic menu.Check the solenoid valve.D791-4/ K1:17 – Y6011/2ATTACH,menu 177.7.5 Control valve attachment
451Redundant voltage feedleft to Control unit KID(D795) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.795/K1:7CAN/ POWER, menu 1411.5.1.2 Redundant voltage feed of Control units
452Redundant voltage feed right to Control unit KID (D795) does not arrive.Check cable harness between the control unit and the component with diagnostic menu.795/K1:8CAN/POWER,menu 1411.5.1.2 Redundant voltage feed of Control units
CodeDescriptionLimitationActionConnection and componentDiagnostic menuGroup
460No messages received on CAN-buffer 1.Incorrect values in operating menus.Use diagnostic menu to check CAN-busD795/K1:10,K1:11,K1:12,K1:13CAN/ POWER, menu 1, 2, 2111.6.2 RedundantCAN-bus
461No messages received on CAN-buffer 2.Error codes from other Control units cannot be shown.Use diagnostic menu to check CAN-busD795/K1:5, K1:6CAN/ POWER,menu 1, 2,2111.6.2 Redundant CAN-bus
500Time for service.Check that service has been performed. If service is done according to Kalmar Industries service intervals, reset the service indicator, see tab 8 Control system, group 8.2.6 Service indicator.8.2.6 Service indicator